<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Industry I/O module | Singapore IOT, GPS, Modem, RTU, SMS Gateway, AI Video Analysis System</title>
	<atom:link href="https://www.grep.sg/product-category/industry-io-module/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.grep.sg</link>
	<description>Grep Tech Pte Ltd</description>
	<lastBuildDate>Sat, 28 Mar 2026 17:43:36 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.6.5</generator>

<image>
	<url>https://www.grep.sg/wp-content/uploads/2020/04/cropped-gt_new_logo_square-32x32.png</url>
	<title>Industry I/O module | Singapore IOT, GPS, Modem, RTU, SMS Gateway, AI Video Analysis System</title>
	<link>https://www.grep.sg</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">169875391</site>	<item>
		<title>Ethernet Remote I/O Module M420T</title>
		<link>https://www.grep.sg/product/ethernet-remote-i-o-module-m420t/</link>
					<comments>https://www.grep.sg/product/ethernet-remote-i-o-module-m420t/#respond</comments>
		
		<dc:creator><![CDATA[robin]]></dc:creator>
		<pubDate>Wed, 17 Nov 2021 09:52:24 +0000</pubDate>
				<guid isPermaLink="false">https://www.grep.sg/?post_type=product&#038;p=4313</guid>

					<description><![CDATA[<ul>
 	<li class="p1"><span class="s1">Rated Voltage: 12 ~ 36VDC;</span></li>
 	<li class="p1"><span class="s1">16DO+1RJ45+1 RS485 Serial port, supports Modbus RTU Master or slave, can extend I/O modules;</span></li>
 	<li class="p1"><span class="s1">DO Sink or Pulse Output.</span></li>
</ul>]]></description>
										<content:encoded><![CDATA[<p class="p1"><span class="s1">The M420T Ethernet Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1 Industrial 10/100M adaptive Ethernet module inside. It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.</span></p>
<p class="p3"><a href="https://www.grep.sg/wp-content/uploads/2021/11/M420T_info.jpeg"><img fetchpriority="high" decoding="async" class="aligncenter size-full wp-image-4315" src="https://www.grep.sg/wp-content/uploads/2021/11/M420T_info.jpeg" alt="" width="2080" height="2080" srcset="https://www.grep.sg/wp-content/uploads/2021/11/M420T_info.jpeg 2080w, https://www.grep.sg/wp-content/uploads/2021/11/M420T_info-1280x1280.jpeg 1280w, https://www.grep.sg/wp-content/uploads/2021/11/M420T_info-980x980.jpeg 980w, https://www.grep.sg/wp-content/uploads/2021/11/M420T_info-480x480.jpeg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 2080px, 100vw" /></a></p>
<p class="p5"><span class="s1">The M420T Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements. The M420T Ethernet Remote I/O module provides 16 digital outputs, supports 10Hz~300Khz high speed pulse output or relay outputs. All of the I/O with high sampling frequency and special filtering strategy to ensure it’s reliable.</span></p>
<h2 class="p7"><span class="s1">Specifications:</span></h2>
<table class="t1" style="border-style: solid; border-color: #000000;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="td1" colspan="2" valign="middle">
<p class="p8"><span class="s1"><b>Ethernet Remote I/O Module Specifications</b></span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p9"><span class="s1"><b>• Digital Output</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Type</span></p>
</td>
<td class="td4" valign="middle">
<p class="p11"><span class="s1">Sink</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">I/O Mode</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">DO or Pulse Output</span></p>
</td>
</tr>
<tr>
<td class="td6" valign="middle">
<p class="p10"><span class="s1">Pulse Output Frequency</span></p>
</td>
<td class="td7" valign="middle">
<p class="p11"><span class="s1">10Hz~300KHz(Only the 1</span><span class="s2"><sup>st</sup></span><span class="s1"> Channel can be used as high speed pulse outputs)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Over-Voltage Protection</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">50 VDC</span></p>
</td>
</tr>
<tr>
<td class="td8" valign="middle">
<p class="p10"><span class="s1">Over-Temperature Shutdown</span></p>
</td>
<td class="td9" valign="middle">
<p class="p11"><span class="s1">175°C (typical), 150°C (min.)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Load Current</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">Max. 500 mA per channel</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Digital sampling frequency</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">500Hz</span></p>
</td>
</tr>
<tr>
<td class="td6" valign="middle">
<p class="p10"><span class="s1">Isolation</span></p>
</td>
<td class="td7" valign="middle">
<p class="p11"><span class="s1">If DO is Sink type, then no isolation. If it is Relay, then is electrical isolation.</span></p>
</td>
</tr>
<tr>
<td class="td10" colspan="2" valign="middle">
<p class="p9"><span class="s1"><b>• Working Power Requirements</b></span></p>
</td>
</tr>
<tr>
<td class="td8" valign="middle">
<p class="p10"><span class="s1">Input Voltage</span></p>
</td>
<td class="td11" valign="middle">
<p class="p11"><span class="s1">12 to 36 VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Input Current</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">139 mA @ 24 VDC</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p9"><span class="s1"><b>• LAN</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Ethernet</span></p>
</td>
<td class="td4" valign="middle">
<p class="p11"><span class="s1">10/100 Mbps, RJ45 ports</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Protection</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">15KV ESD Protection</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Protocols</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">Modbus TCP, TCP/IP,MQTT, TCP Server, TCP Client</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Max. TCP Connection</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">5</span></p>
</td>
</tr>
<tr>
<td class="td10" colspan="2" valign="middle">
<p class="p9"><span class="s1"><b>• Serial Port</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">RS485</span></p>
</td>
<td class="td4" valign="middle">
<p class="p12"><span class="s1">MODBUS- RTU Protocol, Modbus-ASCII Protocol</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Protection</span></p>
</td>
<td class="td5" valign="middle">
<p class="p12"><span class="s1">15KV ESD Protection</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Modbus Slave address</span></p>
</td>
<td class="td5" valign="middle">
<p class="p12"><span class="s1">1~255</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Baud Rate</span></p>
</td>
<td class="td5" valign="middle">
<p class="p12"><span class="s1">1200,2400,4800,9600,19200,38400,57600,115200,128000Bps;</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Mapping registers</span></p>
</td>
<td class="td5" valign="middle">
<p class="p12"><span class="s1">Bit Type: 300 Registers, 16-Bit Type: 300 Registers.300</span></p>
</td>
</tr>
<tr>
<td class="td10" colspan="2" valign="middle">
<p class="p9"><span class="s1"><b>• Physical Characteristics</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Wiring</span></p>
</td>
<td class="td4" valign="middle">
<p class="p11"><span class="s1">I/O cable max. 14 AWG</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Dimensions</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">105 x 88 x 30 mm</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Weight</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">Under 205 g</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Mounting</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">DIN rail or wall</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p9"><span class="s1"><b>• Environmental Limits</b></span></p>
</td>
</tr>
<tr>
<td class="td6" valign="middle">
<p class="p10"><span class="s1">Operating Temperature</span></p>
</td>
<td class="td12" valign="middle">
<p class="p11"><span class="s1">Standard Models: -10 to 60°C (14 to 140°F)</span> <span class="s1">Wide Temp. Models: -40 to 75°C (-40 to 167°F)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Storage Temperature</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">-40 to 85°C (-40 to 185°F)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Ambient Relative Humidity</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">5 to 95% (non-condensing)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Altitude</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">Up to 3000 m</span></p>
</td>
</tr>
</tbody>
</table>
<h2 class="p7"><span class="s1">Features:</span></h2>
<p class="p1"><span class="s1">1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;</span></p>
<p class="p1"><span class="s1">2. Wide range power supply 12 ~ 36VDC with over voltage and phase-reversal protection;</span></p>
<p class="p1"><span class="s1">3. Management and configuration via LAN connection configuration software for easy operation and maintenance;</span></p>
<p class="p1"><span class="s1">4. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP protocol;</span></p>
<p class="p1"><span class="s1">5. 16 digital output or relay output, supports 10Hz~300KHz high speed pulse output;</span></p>
<p class="p1"><span class="s1">6. High sampling frequency and special filtering strategy to ensure reliability;</span></p>
<p class="p1"><span class="s1">7. 1 RS485 Serial port, supports Modbus RTU/ASCII Master, can extend I/O modules;</span></p>
<p class="p1"><span class="s1">8. Supports register mapping function and extend I/O inquiry strategy;</span></p>
<p class="p1"><span class="s1">9.Provides 1 channel 12~36VDC power source output for external device, saving wiring cost;</span></p>
<p class="p1"><span class="s1">10.LED instructions work status, with reset button to reset, easy on-site installation and commissioning;</span></p>
<p class="p1"><span class="s1">11.Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;</span></p>
<p class="p1"><span class="s1">12.Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.</span></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.grep.sg/product/ethernet-remote-i-o-module-m420t/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">4313</post-id>	</item>
		<item>
		<title>Ethernet Remote I/O Module M410T</title>
		<link>https://www.grep.sg/product/ethernet-remote-i-o-module-m410t/</link>
					<comments>https://www.grep.sg/product/ethernet-remote-i-o-module-m410t/#respond</comments>
		
		<dc:creator><![CDATA[robin]]></dc:creator>
		<pubDate>Wed, 17 Nov 2021 09:39:23 +0000</pubDate>
				<guid isPermaLink="false">https://www.grep.sg/?post_type=product&#038;p=4307</guid>

					<description><![CDATA[<ul>
 	<li class="p1"><span class="s1">Rated Voltage: 12 ~ 36VDC;</span></li>
 	<li class="p1"><span class="s1">16DIN+1RJ45+1 RS485 Serial port, supports Modbus RTU Master or slave, can extend I/O modules;</span></li>
 	<li class="p1"><span class="s1">Wet Contact (NPN or PNP), Dry Contact.</span></li>
</ul>]]></description>
										<content:encoded><![CDATA[<p class="p1"><span class="s1">The M410T Ethernet Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1 Industrial 10/100M adaptive Ethernet module inside. It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.</span></p>
<p class="p3"><a href="https://www.grep.sg/wp-content/uploads/2021/11/M410T_info.jpeg"><img decoding="async" class="aligncenter size-full wp-image-4308" src="https://www.grep.sg/wp-content/uploads/2021/11/M410T_info.jpeg" alt="" width="2080" height="2080" srcset="https://www.grep.sg/wp-content/uploads/2021/11/M410T_info.jpeg 2080w, https://www.grep.sg/wp-content/uploads/2021/11/M410T_info-1280x1280.jpeg 1280w, https://www.grep.sg/wp-content/uploads/2021/11/M410T_info-980x980.jpeg 980w, https://www.grep.sg/wp-content/uploads/2021/11/M410T_info-480x480.jpeg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 2080px, 100vw" /></a></p>
<p class="p1"><span class="s1">The M410T Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.</span></p>
<p class="p1"><span class="s1">The M410T Ethernet Remote I/O module provides 16 optical-isolated digital inputs, supports max. 700KHz high speed pulse counter. All of the I/O with high sampling frequency and special filtering strategy to ensure it’s reliable.</span></p>
<h2 class="p5"><span class="s1">Specifications:</span></h2>
<table class="t1" style="border-style: solid; border-color: #000000;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="td1" colspan="2" valign="middle">
<p class="p6"><span class="s1"><b>Ethernet Remote I/O Module Specifications</b></span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Digital Input</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Sensor Type</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Wet Contact (NPN or PNP), Dry Contact</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">I/O Mode</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">DI or Event Counter</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p8"><span class="s1">Dry Contact</span></p>
</td>
<td class="td6" valign="middle">
<p class="p9"><span class="s1">• On: short to GND=1</span> <span class="s1">• Off: open=0</span></p>
</td>
</tr>
<tr>
<td class="td7" valign="middle">
<p class="p8"><span class="s1">Wet Contact (DI to COM)</span></p>
</td>
<td class="td8" valign="middle">
<p class="p9"><span class="s1">• On: 10 to 30 VDC=1 </span> <span class="s1">• Off: 0 to 3 VDC=0</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p8"><span class="s1">Counter Frequency</span></p>
</td>
<td class="td6" valign="middle">
<p class="p9"><span class="s1">Max. 700Khz (Only the 1</span><span class="s3"><sup>st</sup></span><span class="s1"> Channel can be used as high speed pulse counter)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Digital sampling frequency</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">500Hz</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Digital filtering strategy</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Continues 3 times</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Isolation</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Optical Isolated,3k VDC or 2k Vrms</span></p>
</td>
</tr>
<tr>
<td class="td9" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Working Power Requirements</b></span></p>
</td>
</tr>
<tr>
<td class="td7" valign="middle">
<p class="p8"><span class="s1">Input Voltage</span></p>
</td>
<td class="td8" valign="middle">
<p class="p9"><span class="s1">12 to 36 VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Input Current</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">139 mA @ 24 VDC</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Power Output</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Output Voltage</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">12 to 36 VDC</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Output Current</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">139 mA @ 24 VDC</span></p>
</td>
</tr>
<tr>
<td class="td9" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• LAN</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Ethernet</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">10/100 Mbps, RJ45 ports</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Protection</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">15KV ESD Protection</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Protocols</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Modbus TCP, TCP/IP,MQTT,TCP Server, TCP Client</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Max. TCP Connection</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">5</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Serial Port</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">RS485</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">MODBUS- RTU Protocol, Modbus-ASCII Protocol</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Protection</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">15KV ESD Protection</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Modbus Slave address</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">1~255</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Baud Rate</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">1200,2400,4800,9600,19200,38400,57600,115200,128000Bps;</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Mapping registers</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">Bit Type: 300 Registers, 16-Bit Type: 300 Registers.</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Physical Characteristics</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Wiring</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">I/O cable max. 14 AWG</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Dimensions</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">105 x 88 x 30 mm</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Weight</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Under 205 g</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Mounting</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">DIN rail or wall</span></p>
</td>
</tr>
<tr>
<td class="td9" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Environmental Limits</b></span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p8"><span class="s1">Operating Temperature</span></p>
</td>
<td class="td6" valign="middle">
<p class="p9"><span class="s1">Standard Models: -10 to 60°C (14 to 140°F)</span> <span class="s1">Wide Temp. Models: -40 to 75°C (-40 to 167°F)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Storage Temperature</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">-40 to 85°C (-40 to 185°F)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Ambient Relative Humidity</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">5 to 95% (non-condensing)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Altitude</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Up to 3000 m</span></p>
</td>
</tr>
</tbody>
</table>
<h2 class="p5"><span class="s1">Features:</span></h2>
<p class="p1"><span class="s1">1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;</span></p>
<p class="p1"><span class="s1">2. Wide range power supply 12 ~ 36VDC with over voltage and phase-reversal protection;</span></p>
<p class="p1"><span class="s1">3. Management and configuration via LAN connection configuration software for easy operation and maintenance;</span></p>
<p class="p1"><span class="s1">5. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP protocol;</span></p>
<p class="p1"><span class="s1">6. 16 optical isolated digital input, supports max. 700Khz high speed pulse counter;</span></p>
<p class="p1"><span class="s1">7. High sampling frequency and special filtering strategy to ensure reliability;</span></p>
<p class="p1"><span class="s1">8. 1 RS485 Serial port, supports Modbus RTU/ASCII Master, can extend I/O modules;</span></p>
<p class="p1"><span class="s1">9. Supports register mapping function and extend I/O inquiry strategy;</span></p>
<p class="p1"><span class="s1">10.Provides 1 channel 12~36VDC power source output for external device, saving wiring cost;</span></p>
<p class="p1"><span class="s1">11.LED instructions work status, with reset button to reset, easy on-site installation and commissioning;</span></p>
<p class="p1"><span class="s1">12.Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;</span></p>
<p class="p1"><span class="s1">13.Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.</span></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.grep.sg/product/ethernet-remote-i-o-module-m410t/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">4307</post-id>	</item>
		<item>
		<title>Ethernet Remote I/O Module M340T</title>
		<link>https://www.grep.sg/product/ethernet-remote-i-o-module-m340t/</link>
					<comments>https://www.grep.sg/product/ethernet-remote-i-o-module-m340t/#respond</comments>
		
		<dc:creator><![CDATA[robin]]></dc:creator>
		<pubDate>Wed, 17 Nov 2021 09:32:06 +0000</pubDate>
				<guid isPermaLink="false">https://www.grep.sg/?post_type=product&#038;p=4303</guid>

					<description><![CDATA[<ul>
 	<li class="p1"><span class="s1">Rated Voltage: 12 ~ 36VDC;</span></li>
 	<li class="p1"><span class="s1">8RTD+1RJ45+1 RS485 Serial port, supports Modbus RTU Master or slave, can extend I/O modules;</span></li>
 	<li class="p1"><span class="s1">4 RTD input, supports PT100 and PT1000 resistance sensor, compatible 2 or 3 wires.</span></li>
</ul>]]></description>
										<content:encoded><![CDATA[<p class="p1"><span class="s1">The M340T Ethernet Remote I/O Module is an industrial class, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1 Industrial 10/100M adaptive Ethernet module inside. It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.</span></p>
<p class="p3"><a href="https://www.grep.sg/wp-content/uploads/2021/11/M340T_info.jpeg"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-4304" src="https://www.grep.sg/wp-content/uploads/2021/11/M340T_info.jpeg" alt="" width="2080" height="2080" srcset="https://www.grep.sg/wp-content/uploads/2021/11/M340T_info.jpeg 2080w, https://www.grep.sg/wp-content/uploads/2021/11/M340T_info-1280x1280.jpeg 1280w, https://www.grep.sg/wp-content/uploads/2021/11/M340T_info-980x980.jpeg 980w, https://www.grep.sg/wp-content/uploads/2021/11/M340T_info-480x480.jpeg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 2080px, 100vw" /></a></p>
<p class="p1"><span class="s1">The M340T Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.</span></p>
<p class="p1"><span class="s1">The M340T Ethernet Remote I/O module provides 8 RTD inputs, supports PT100 and PT1000 resistance sensor, compatible 2 or 3 wires, the resolution is 0.1°C. All of the I/O with high sampling frequency and special filtering strategy to ensure it’s reliable.</span></p>
<h2 class="p5"><span class="s1">Specifications:</span></h2>
<table class="t1" style="border-style: solid; border-color: #000000;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="td1" colspan="2" valign="middle">
<p class="p1"><span class="s1">Ethernet Remote I/O Module Specifications</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p1"><span class="s1">• RTD Input</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p1"><span class="s1">Sensor Type</span></p>
</td>
<td class="td4" valign="middle">
<p class="p1"><span class="s1">PT100 or PT1000</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">Resolution</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">0.1°C or 0.1 ohm</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p1"><span class="s1">Input Connection</span></p>
</td>
<td class="td4" valign="middle">
<p class="p1"><span class="s1">2- or 3-wire</span></p>
</td>
</tr>
<tr>
<td class="td7" valign="middle">
<p class="p1"><span class="s1">Accuracy</span></p>
</td>
<td class="td8" valign="middle">
<p class="p1"><span class="s1">±0.1% FSR @ 25°C ±0.3% FSR @ -40 and 75°C</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p1"><span class="s1">Sampling frequency</span></p>
</td>
<td class="td4" valign="middle">
<p class="p1"><span class="s1">20Hz</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">Isolation</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">No</span></p>
</td>
</tr>
<tr>
<td class="td1" colspan="2" valign="middle">
<p class="p1"><span class="s1">• Working Power Requirements</span></p>
</td>
</tr>
<tr>
<td class="td7" valign="middle">
<p class="p1"><span class="s1">Input Voltage</span></p>
</td>
<td class="td8" valign="middle">
<p class="p1"><span class="s1">12~36VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p1"><span class="s1">Input Current</span></p>
</td>
<td class="td4" valign="middle">
<p class="p1"><span class="s1">139 mA @ 24 VDC</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p1"><span class="s1">• LAN</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p1"><span class="s1">Ethernet</span></p>
</td>
<td class="td4" valign="middle">
<p class="p1"><span class="s1">10/100 Mbps, RJ45 ports</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">Protection</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">15KV ESD Protection</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p1"><span class="s1">Protocols</span></p>
</td>
<td class="td4" valign="middle">
<p class="p1"><span class="s1">Modbus TCP, TCP/IP</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">Max. TCP Connection</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">5</span></p>
</td>
</tr>
<tr>
<td class="td1" colspan="2" valign="middle">
<p class="p1"><span class="s1">• Serial Port</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">RS485</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">MODBUS- RTU Protocol, Modbus-ASCII Protocol</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p1"><span class="s1">Protection</span></p>
</td>
<td class="td4" valign="middle">
<p class="p1"><span class="s1">15KV ESD Protection</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">Modbus Slave address</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">1~255</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p1"><span class="s1">Baud Rate</span></p>
</td>
<td class="td4" valign="middle">
<p class="p1"><span class="s1">1200,2400,4800,9600,19200,38400,57600,115200,128000Bps;</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">Mapping registers</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">Bit Type: 300 Registers, 16-Bit Type: 300 Registers.300</span></p>
</td>
</tr>
<tr>
<td class="td1" colspan="2" valign="middle">
<p class="p1"><span class="s1">• Physical Characteristics</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">Wiring</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">I/O cable max. 14 AWG</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p1"><span class="s1">Dimensions</span></p>
</td>
<td class="td4" valign="middle">
<p class="p1"><span class="s1">105 x 88 x 30 mm</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">Weight</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">Under 205 g</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p1"><span class="s1">Mounting</span></p>
</td>
<td class="td4" valign="middle">
<p class="p1"><span class="s1">DIN rail or wall</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p1"><span class="s1">• Environmental Limits</span></p>
</td>
</tr>
<tr>
<td class="td9" valign="middle">
<p class="p1"><span class="s1">Operating Temperature</span></p>
</td>
<td class="td10" valign="middle">
<p class="p1"><span class="s1">Standard Models: -10 to 60°C (14 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F)</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">Storage Temperature</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">-40 to 85°C (-40 to 185°F)</span></p>
</td>
</tr>
<tr>
<td class="td9" valign="middle">
<p class="p1"><span class="s1">Ambient Relative Humidity</span></p>
</td>
<td class="td10" valign="middle">
<p class="p1"><span class="s1">5 to 95% (non-condensing)</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">Altitude</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">Up to 3000 m</span></p>
</td>
</tr>
</tbody>
</table>
<h2 class="p5"><span class="s1">Features:</span></h2>
<p class="p1"><span class="s1">1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;</span></p>
<p class="p1"><span class="s1">2. Wide range power supply 12 ~ 36VDC with over voltage and phase-reversal protection;</span></p>
<p class="p1"><span class="s1">3. Management and configuration via LAN connection configuration software for easy operation and maintenance;</span></p>
<p class="p1"><span class="s1">4. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP protocol;</span></p>
<p class="p1"><span class="s1">5. 8 RTD input, supports PT100 and PT1000 resistance sensor, compatible 2 or 3 wires;</span></p>
<p class="p1"><span class="s1">6. High sampling frequency and special filtering strategy to ensure reliability;</span></p>
<p class="p1"><span class="s1">7. 1 RS485 Serial port, supports Modbus RTU/ASCII Master, can extend I/O modules;</span></p>
<p class="p1"><span class="s1">8. Supports register mapping function and extend I/O inquiry strategy;</span></p>
<p class="p1"><span class="s1">9.Provides 1 channel 12~36VDC power source output for external device, saving wiring cost;</span></p>
<p class="p1"><span class="s1">10.LED instructions work status, with reset button to reset, easy on-site installation and commissioning;</span></p>
<p class="p1"><span class="s1">11.Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;</span></p>
<p class="p1"><span class="s1">12.Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.</span></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.grep.sg/product/ethernet-remote-i-o-module-m340t/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">4303</post-id>	</item>
		<item>
		<title>Ethernet Remote I/O Module M330T</title>
		<link>https://www.grep.sg/product/ethernet-remote-i-o-module-m330t/</link>
					<comments>https://www.grep.sg/product/ethernet-remote-i-o-module-m330t/#respond</comments>
		
		<dc:creator><![CDATA[robin]]></dc:creator>
		<pubDate>Wed, 17 Nov 2021 09:27:05 +0000</pubDate>
				<guid isPermaLink="false">https://www.grep.sg/?post_type=product&#038;p=4301</guid>

					<description><![CDATA[<ul>
 	<li class="p1"><span class="s1">Rated Voltage: 12 ~ 36VDC;</span></li>
 	<li class="p1"><span class="s1">8AIN+1RJ45+1 RS485 Serial port, supports Modbus RTU Master or slave, can extend I/O modules;</span></li>
 	<li class="p1"><span class="s1">4 isolated analog input, 12-bit resolution, supports 0~20mA,4~20mA,0-5VDC, 0-10VDC.</span></li>
</ul>]]></description>
										<content:encoded><![CDATA[<p class="p1"><span class="s1">The M330T Ethernet Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1 Industrial 10/100M adaptive Ethernet module inside. It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.</span></p>
<p class="p3"><a href="https://www.grep.sg/wp-content/uploads/2021/11/M330T_info.jpeg"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-4302" src="https://www.grep.sg/wp-content/uploads/2021/11/M330T_info.jpeg" alt="" width="2080" height="2080" srcset="https://www.grep.sg/wp-content/uploads/2021/11/M330T_info.jpeg 2080w, https://www.grep.sg/wp-content/uploads/2021/11/M330T_info-1280x1280.jpeg 1280w, https://www.grep.sg/wp-content/uploads/2021/11/M330T_info-980x980.jpeg 980w, https://www.grep.sg/wp-content/uploads/2021/11/M330T_info-480x480.jpeg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 2080px, 100vw" /></a></p>
<p class="p1"><span class="s1">The M330T Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.</span></p>
<p class="p1"><span class="s1">The M330T Ethernet Remote I/O module provides 8 isolated 12bits analog inputs, supports 0~5V,0~10V,4~20mA,0~20mA analog signal. All of the I/O with high sampling frequency and special filtering strategy to ensure it’s reliable.</span></p>
<h2 class="p5"><span class="s1">Specifications:</span></h2>
<table class="t1" style="border-style: solid; border-color: #000000;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="td1" colspan="2" valign="middle">
<p class="p6"><span class="s1"><b>Ethernet Remote I/O Module Specifications</b></span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Analog Input</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Type</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Differential input</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Resolution</span></p>
</td>
<td class="td5" valign="middle">
<p class="p9"><span class="s1">12 bits</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">I/O Mode</span></p>
</td>
<td class="td5" valign="middle">
<p class="p9"><span class="s1">Voltage / Current (jumper selectable)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Input Range</span></p>
</td>
<td class="td5" valign="middle">
<p class="p9"><span class="s1">0 to 10 VDC, 0 to 20 mA, 4 to 20 mA, 4 to 20 mA</span></p>
</td>
</tr>
<tr>
<td class="td6" valign="middle">
<p class="p8"><span class="s1">Accuracy</span></p>
</td>
<td class="td7" valign="middle">
<p class="p9"><span class="s1">±0.1% FSR @ 25°C</span> <span class="s1">±0.3% FSR @ -10 and 60°C</span> <span class="s1">±0.5% FSR @ -40 and 75°C</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Sampling frequency</span></p>
</td>
<td class="td5" valign="middle">
<p class="p9"><span class="s1">20Hz</span></p>
</td>
</tr>
<tr>
<td class="td8" valign="middle">
<p class="p8"><span class="s1">Built-in Resistor for Current Input</span></p>
</td>
<td class="td9" valign="middle">
<p class="p9"><span class="s1">162 ohms</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Isolation</span></p>
</td>
<td class="td5" valign="middle">
<p class="p9"><span class="s1">Electrical isolation</span></p>
</td>
</tr>
<tr>
<td class="td10" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Working Power Requirements</b></span></p>
</td>
</tr>
<tr>
<td class="td11" valign="middle">
<p class="p8"><span class="s1">Input Voltage</span></p>
</td>
<td class="td12" valign="middle">
<p class="p9"><span class="s1">12 to 36 VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Input Current</span></p>
</td>
<td class="td5" valign="middle">
<p class="p9"><span class="s1">139 mA @ 24 VDC</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Power Output</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Output Voltage</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">12 to 36 VDC</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Output Current</span></p>
</td>
<td class="td5" valign="middle">
<p class="p9"><span class="s1">139 mA @ 24 VDC</span></p>
</td>
</tr>
<tr>
<td class="td10" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• LAN</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Ethernet</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">10/100 Mbps, RJ45 ports</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Protection</span></p>
</td>
<td class="td5" valign="middle">
<p class="p9"><span class="s1">15KV ESD Protection</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Protocols</span></p>
</td>
<td class="td5" valign="middle">
<p class="p9"><span class="s1">Modbus TCP, TCP/IP</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Max. TCP Connection</span></p>
</td>
<td class="td5" valign="middle">
<p class="p9"><span class="s1">5</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Serial Port</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">RS485</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">MODBUS- RTU Protocol, Modbus-ASCII Protocol</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Protection</span></p>
</td>
<td class="td5" valign="middle">
<p class="p10"><span class="s1">15KV ESD Protection</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Modbus Slave address</span></p>
</td>
<td class="td5" valign="middle">
<p class="p10"><span class="s1">1~255</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Baud Rate</span></p>
</td>
<td class="td5" valign="middle">
<p class="p10"><span class="s1">1200,2400,4800,9600,19200,38400,57600,115200,128000Bps;</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Mapping registers</span></p>
</td>
<td class="td5" valign="middle">
<p class="p10"><span class="s1">Bit Type: 300 Registers, 16-Bit Type: 300 Registers.</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Physical Characteristics</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Wiring</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">I/O cable max. 14 AWG</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Dimensions</span></p>
</td>
<td class="td5" valign="middle">
<p class="p9"><span class="s1">105 x 88 x 30 mm</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Weight</span></p>
</td>
<td class="td5" valign="middle">
<p class="p9"><span class="s1">Under 205 g</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Mounting</span></p>
</td>
<td class="td5" valign="middle">
<p class="p9"><span class="s1">DIN rail or wall</span></p>
</td>
</tr>
<tr>
<td class="td10" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Environmental Limits</b></span></p>
</td>
</tr>
<tr>
<td class="td8" valign="middle">
<p class="p8"><span class="s1">Operating Temperature</span></p>
</td>
<td class="td13" valign="middle">
<p class="p9"><span class="s1">Standard Models: -10 to 60°C (14 to 140°F)</span> <span class="s1">Wide Temp. Models: -40 to 75°C (-40 to 167°F)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Storage Temperature</span></p>
</td>
<td class="td5" valign="middle">
<p class="p9"><span class="s1">-40 to 85°C (-40 to 185°F)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Ambient Relative Humidity</span></p>
</td>
<td class="td5" valign="middle">
<p class="p9"><span class="s1">5 to 95% (non-condensing)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Altitude</span></p>
</td>
<td class="td5" valign="middle">
<p class="p9"><span class="s1">Up to 3000 m</span></p>
</td>
</tr>
</tbody>
</table>
<h2 class="p5"><span class="s1">Features:</span></h2>
<p class="p1"><span class="s1">1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;</span></p>
<p class="p1"><span class="s1">2. Wide range power supply 12 ~ 36VDC with over voltage and phase-reversal protection;</span></p>
<p class="p1"><span class="s1">3. Management and configuration via LAN connection configuration software for easy operation and maintenance;</span></p>
<p class="p1"><span class="s1">4. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP protocol;</span></p>
<p class="p1"><span class="s1">5. 8 isolated analog input, 12-bit resolution, supports 0~20mA,4~20mA,0-5VDC, 0-10VDC;</span></p>
<p class="p1"><span class="s1">6. High sampling frequency and special filtering strategy to ensure reliability;</span></p>
<p class="p1"><span class="s1">7. 1 RS485 Serial port, supports Modbus RTU/ASCII Master, can extend I/O modules;</span></p>
<p class="p1"><span class="s1">8. Supports register mapping function and extend I/O inquiry strategy;</span></p>
<p class="p1"><span class="s1">9.Provides 1 channel 12~36VDC power source output for external device, saving wiring cost;</span></p>
<p class="p1"><span class="s1">10.LED instructions work status, with reset button to reset, easy on-site installation and commissioning;</span></p>
<p class="p1"><span class="s1">11.Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;</span></p>
<p class="p1"><span class="s1">12.Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.</span></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.grep.sg/product/ethernet-remote-i-o-module-m330t/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">4301</post-id>	</item>
		<item>
		<title>Ethernet Remote I/O Module M320T</title>
		<link>https://www.grep.sg/product/ethernet-remote-i-o-module-m320t/</link>
					<comments>https://www.grep.sg/product/ethernet-remote-i-o-module-m320t/#respond</comments>
		
		<dc:creator><![CDATA[robin]]></dc:creator>
		<pubDate>Wed, 17 Nov 2021 09:21:23 +0000</pubDate>
				<guid isPermaLink="false">https://www.grep.sg/?post_type=product&#038;p=4299</guid>

					<description><![CDATA[<ul>
 	<li class="p1"><span class="s1">Rated Voltage: 12 ~ 36VDC;</span></li>
 	<li class="p1"><span class="s1">8DO+1RJ45+1 RS485 Serial port, supports Modbus RTU Master or slave, can extend I/O modules;</span></li>
 	<li class="p1"><span class="s1">DO Sink or Pulse Output.</span></li>
</ul>]]></description>
										<content:encoded><![CDATA[<p class="p1"><span class="s1">The M320T Ethernet Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1 Industrial 10/100M adaptive Ethernet module inside. It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.</span></p>
<p class="p3"><a href="https://www.grep.sg/wp-content/uploads/2021/11/M320T_info.jpeg"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-4300" src="https://www.grep.sg/wp-content/uploads/2021/11/M320T_info.jpeg" alt="" width="2080" height="2080" srcset="https://www.grep.sg/wp-content/uploads/2021/11/M320T_info.jpeg 2080w, https://www.grep.sg/wp-content/uploads/2021/11/M320T_info-1280x1280.jpeg 1280w, https://www.grep.sg/wp-content/uploads/2021/11/M320T_info-980x980.jpeg 980w, https://www.grep.sg/wp-content/uploads/2021/11/M320T_info-480x480.jpeg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 2080px, 100vw" /></a></p>
<p class="p5"><span class="s1">The M320T Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements. The M320T Ethernet Remote I/O module provides 8 digital outputs, supports 10Hz~300Khz high speed pulse output or relay outputs. All of the I/O with high sampling frequency and special filtering strategy to ensure it’s reliable.</span></p>
<h2 class="p7"><span class="s1">Specifications:</span></h2>
<table class="t1" style="border-style: solid; border-color: #000000;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="td1" colspan="2" valign="middle">
<p class="p8"><span class="s1"><b>Ethernet Remote I/O Module Specifications</b></span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p9"><span class="s1"><b>• Digital Output</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Type</span></p>
</td>
<td class="td4" valign="middle">
<p class="p11"><span class="s1">Sink</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">I/O Mode</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">DO or Pulse Output</span></p>
</td>
</tr>
<tr>
<td class="td6" valign="middle">
<p class="p10"><span class="s1">Pulse Output Frequency</span></p>
</td>
<td class="td7" valign="middle">
<p class="p11"><span class="s1">10Hz~300KHz(Only the 1</span><span class="s2"><sup>st</sup></span><span class="s1"> Channel can be used as high speed pulse outputs)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Over-Voltage Protection</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">50 VDC</span></p>
</td>
</tr>
<tr>
<td class="td8" valign="middle">
<p class="p10"><span class="s1">Over-Temperature Shutdown</span></p>
</td>
<td class="td9" valign="middle">
<p class="p11"><span class="s1">175°C (typical), 150°C (min.)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Load Current</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">Max. 500 mA per channel</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Digital sampling frequency</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">500Hz</span></p>
</td>
</tr>
<tr>
<td class="td6" valign="middle">
<p class="p10"><span class="s1">Isolation</span></p>
</td>
<td class="td7" valign="middle">
<p class="p11"><span class="s1">If DO is Sink type, then no isolation. If it is Relay, then is electrical isolation.</span></p>
</td>
</tr>
<tr>
<td class="td10" colspan="2" valign="middle">
<p class="p9"><span class="s1"><b>• Working Power Requirements</b></span></p>
</td>
</tr>
<tr>
<td class="td8" valign="middle">
<p class="p10"><span class="s1">Input Voltage</span></p>
</td>
<td class="td11" valign="middle">
<p class="p11"><span class="s1">12 to 36 VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Input Current</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">139 mA @ 24 VDC</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p9"><span class="s1"><b>• LAN</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Ethernet</span></p>
</td>
<td class="td4" valign="middle">
<p class="p11"><span class="s1">10/100 Mbps, RJ45 ports</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Protection</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">15KV ESD Protection</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Protocols</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">Modbus TCP, TCP/IP,MQTT, TCP Server, TCP Client</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Max. TCP Connection</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">5</span></p>
</td>
</tr>
<tr>
<td class="td10" colspan="2" valign="middle">
<p class="p9"><span class="s1"><b>• Serial Port</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">RS485</span></p>
</td>
<td class="td4" valign="middle">
<p class="p12"><span class="s1">MODBUS- RTU Protocol, Modbus-ASCII Protocol</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Protection</span></p>
</td>
<td class="td5" valign="middle">
<p class="p12"><span class="s1">15KV ESD Protection</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Modbus Slave address</span></p>
</td>
<td class="td5" valign="middle">
<p class="p12"><span class="s1">1~255</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Baud Rate</span></p>
</td>
<td class="td5" valign="middle">
<p class="p12"><span class="s1">1200,2400,4800,9600,19200,38400,57600,115200,128000Bps;</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Mapping registers</span></p>
</td>
<td class="td5" valign="middle">
<p class="p12"><span class="s1">Bit Type: 300 Registers, 16-Bit Type: 300 Registers.300</span></p>
</td>
</tr>
<tr>
<td class="td10" colspan="2" valign="middle">
<p class="p9"><span class="s1"><b>• Physical Characteristics</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Wiring</span></p>
</td>
<td class="td4" valign="middle">
<p class="p11"><span class="s1">I/O cable max. 14 AWG</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Dimensions</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">105 x 88 x 30 mm</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Weight</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">Under 205 g</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Mounting</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">DIN rail or wall</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p9"><span class="s1"><b>• Environmental Limits</b></span></p>
</td>
</tr>
<tr>
<td class="td6" valign="middle">
<p class="p10"><span class="s1">Operating Temperature</span></p>
</td>
<td class="td12" valign="middle">
<p class="p11"><span class="s1">Standard Models: -10 to 60°C (14 to 140°F)</span> <span class="s1">Wide Temp. Models: -40 to 75°C (-40 to 167°F)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Storage Temperature</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">-40 to 85°C (-40 to 185°F)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Ambient Relative Humidity</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">5 to 95% (non-condensing)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p10"><span class="s1">Altitude</span></p>
</td>
<td class="td5" valign="middle">
<p class="p11"><span class="s1">Up to 3000 m</span></p>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h2 class="p7"><span class="s1">Features:</span></h2>
<p class="p14"><span class="s1">1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;</span></p>
<p class="p14"><span class="s1">2. Wide range power supply 12 ~ 36VDC with over voltage and phase-reversal protection;</span></p>
<p class="p14"><span class="s1">3. Management and configuration via LAN connection configuration software for easy operation and maintenance;</span></p>
<p class="p14"><span class="s1">4. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP protocol;</span></p>
<p class="p14"><span class="s1">5. 8 digital output or relay output, supports 10Hz~300KHz high speed pulse output;</span></p>
<p class="p14"><span class="s1">6. High sampling frequency and special filtering strategy to ensure reliability;</span></p>
<p class="p14"><span class="s1">7. 1 RS485 Serial port, supports Modbus RTU/ASCII Master, can extend I/O modules;</span></p>
<p class="p14"><span class="s1">8. Supports register mapping function and extend I/O inquiry strategy;</span></p>
<p class="p14"><span class="s1">9.Provides 1 channel 12~36VDC power source output for external device, saving wiring cost;</span></p>
<p class="p14"><span class="s1">10.LED instructions work status, with reset button to reset, easy on-site installation and commissioning;</span></p>
<p class="p14"><span class="s1">11.Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;</span></p>
<p class="p14"><span class="s1">12.Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.</span></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.grep.sg/product/ethernet-remote-i-o-module-m320t/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">4299</post-id>	</item>
		<item>
		<title>Ethernet Remote I/O Module M310T</title>
		<link>https://www.grep.sg/product/ethernet-remote-i-o-module-m310t/</link>
					<comments>https://www.grep.sg/product/ethernet-remote-i-o-module-m310t/#respond</comments>
		
		<dc:creator><![CDATA[robin]]></dc:creator>
		<pubDate>Wed, 17 Nov 2021 09:14:46 +0000</pubDate>
				<guid isPermaLink="false">https://www.grep.sg/?post_type=product&#038;p=4293</guid>

					<description><![CDATA[<ul>
 	<li class="p1"><span class="s1">Rated Voltage: 12 ~ 36VDC;</span></li>
 	<li class="p1"><span class="s1">8DIN+1RJ45+1 RS485 Serial port, supports Modbus RTU Master or slave, can extend I/O modules;</span></li>
 	<li class="p1"><span class="s1">Wet Contact (NPN or PNP), Dry Contact.</span></li>
</ul>]]></description>
										<content:encoded><![CDATA[<p class="p1"><span class="s1">The M310T Ethernet Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1 Industrial 10/100M adaptive Ethernet module inside. It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.</span></p>
<p class="p3"><a href="https://www.grep.sg/wp-content/uploads/2021/11/M310T_info.jpeg"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-4294" src="https://www.grep.sg/wp-content/uploads/2021/11/M310T_info.jpeg" alt="" width="2080" height="2080" srcset="https://www.grep.sg/wp-content/uploads/2021/11/M310T_info.jpeg 2080w, https://www.grep.sg/wp-content/uploads/2021/11/M310T_info-1280x1280.jpeg 1280w, https://www.grep.sg/wp-content/uploads/2021/11/M310T_info-980x980.jpeg 980w, https://www.grep.sg/wp-content/uploads/2021/11/M310T_info-480x480.jpeg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 2080px, 100vw" /></a></p>
<p class="p1"><span class="s1">The M310T Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.</span></p>
<p class="p1"><span class="s1">The M310T Ethernet Remote I/O module provides 8 optical-isolated digital inputs, supports max. 700KHz high speed pulse counter. All of the I/O with high sampling frequency and special filtering strategy to ensure it’s reliable.</span></p>
<h2 class="p5"><span class="s1">Specifications:</span></h2>
<table class="t1" style="border-style: solid; border-color: #000000;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="td1" colspan="2" valign="middle">
<p class="p6"><span class="s1"><b>Ethernet Remote I/O Module Specifications</b></span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Digital Input</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Sensor Type</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Wet Contact (NPN or PNP), Dry Contact</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">I/O Mode</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">DI or Event Counter</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p8"><span class="s1">Dry Contact</span></p>
</td>
<td class="td6" valign="middle">
<p class="p9"><span class="s1">• On: short to GND=1</span> <span class="s1">• Off: open=0</span></p>
</td>
</tr>
<tr>
<td class="td7" valign="middle">
<p class="p8"><span class="s1">Wet Contact (DI to COM)</span></p>
</td>
<td class="td8" valign="middle">
<p class="p9"><span class="s1">• On: 10 to 30 VDC=1 </span> <span class="s1">• Off: 0 to 3 VDC=0</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p8"><span class="s1">Counter Frequency</span></p>
</td>
<td class="td6" valign="middle">
<p class="p9"><span class="s1">Max. 700Khz (Only the 1</span><span class="s3"><sup>st</sup></span><span class="s1"> Channel can be used as high speed pulse counter)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Digital sampling frequency</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">500Hz</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Digital filtering strategy</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Continues 3 times</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Isolation</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Optical Isolated,3k VDC or 2k Vrms</span></p>
</td>
</tr>
<tr>
<td class="td9" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Working Power Requirements</b></span></p>
</td>
</tr>
<tr>
<td class="td7" valign="middle">
<p class="p8"><span class="s1">Input Voltage</span></p>
</td>
<td class="td8" valign="middle">
<p class="p9"><span class="s1">12 to 36 VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Input Current</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">139 mA @ 24 VDC</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Power Output</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Output Voltage</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">12 to 36 VDC</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Output Current</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">139 mA @ 24 VDC</span></p>
</td>
</tr>
<tr>
<td class="td9" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• LAN</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Ethernet</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">10/100 Mbps, RJ45 ports</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Protection</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">15KV ESD Protection</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Protocols</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Modbus TCP, TCP/IP, MQTT, TCP Client, TCP Server</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Max. TCP Connection</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">5</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Serial Port</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">RS485</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">MODBUS- RTU Protocol, Modbus-ASCII Protocol</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Protection</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">15KV ESD Protection</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Modbus Slave address</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">1~255</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Baud Rate</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">1200,2400,4800,9600,19200,38400,57600,115200,128000Bps;</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Mapping registers</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">Bit Type: 300 Registers, 16-Bit Type: 300 Registers.</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Physical Characteristics</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Wiring</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">I/O cable max. 14 AWG</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Dimensions</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">105 x 88 x 30 mm</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Weight</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Under 205 g</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Mounting</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">DIN rail or wall</span></p>
</td>
</tr>
<tr>
<td class="td9" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Environmental Limits</b></span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p8"><span class="s1">Operating Temperature</span></p>
</td>
<td class="td6" valign="middle">
<p class="p9"><span class="s1">Standard Models: -10 to 60°C (14 to 140°F)</span> <span class="s1">Wide Temp. Models: -40 to 75°C (-40 to 167°F)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Storage Temperature</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">-40 to 85°C (-40 to 185°F)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Ambient Relative Humidity</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">5 to 95% (non-condensing)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Altitude</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Up to 3000 m</span></p>
</td>
</tr>
</tbody>
</table>
<h2 class="p5"><span class="s1">Features:</span></h2>
<p class="p12"><span class="s1">1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;</span></p>
<p class="p12"><span class="s1">2. Wide range power supply 12 ~ 36VDC with over voltage and phase-reversal protection;</span></p>
<p class="p12"><span class="s1">3. Management and configuration via LAN connection configuration software for easy operation and maintenance;</span></p>
<p class="p12"><span class="s1">4. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP protocol;</span></p>
<p class="p12"><span class="s1">5. 8 optical isolated digital input, supports max. 700Khz high speed pulse counter;</span></p>
<p class="p12"><span class="s1">6. High sampling frequency and special filtering strategy to ensure reliability;</span></p>
<p class="p12"><span class="s1">7. 1 RS485 Serial port, supports Modbus RTU/ASCII Master, can extend I/O modules;</span></p>
<p class="p12"><span class="s1">8. Supports register mapping function and extend I/O inquiry strategy;</span></p>
<p class="p12"><span class="s1">9.Provides 1 channel 12~36VDC power source output for external device, saving wiring cost;</span></p>
<p class="p12"><span class="s1">10.LED instructions work status, with reset button to reset, easy on-site installation and commissioning;</span></p>
<p class="p12"><span class="s1">11.Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;</span></p>
<p class="p12"><span class="s1">12.Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.</span></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.grep.sg/product/ethernet-remote-i-o-module-m310t/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">4293</post-id>	</item>
		<item>
		<title>Ethernet Remote I/O Module M240T</title>
		<link>https://www.grep.sg/product/ethernet-remote-i-o-module-m240t/</link>
					<comments>https://www.grep.sg/product/ethernet-remote-i-o-module-m240t/#respond</comments>
		
		<dc:creator><![CDATA[robin]]></dc:creator>
		<pubDate>Wed, 17 Nov 2021 09:09:27 +0000</pubDate>
				<guid isPermaLink="false">https://www.grep.sg/?post_type=product&#038;p=4291</guid>

					<description><![CDATA[<ul>
 	<li class="p1"><span class="s1">Rated Voltage: 12 ~ 36VDC;</span></li>
 	<li class="p1"><span class="s1">4 RTD+1RJ45+1 RS485 Serial port, supports Modbus RTU Master or slave, can extend I/O modules;</span></li>
 	<li class="p1"><span class="s1">4 RTD input, supports PT100 and PT1000 resistance sensor, compatible 2 or 3 wires.</span></li>
</ul>]]></description>
										<content:encoded><![CDATA[<p class="p1"><span class="s1">The M240T Ethernet Remote I/O Module is an industrial class, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1 Industrial 10/100M adaptive Ethernet module inside. It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.</span></p>
<p class="p3"><a href="https://www.grep.sg/wp-content/uploads/2021/11/M240T_info.jpeg"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-4292" src="https://www.grep.sg/wp-content/uploads/2021/11/M240T_info.jpeg" alt="" width="2080" height="2080" srcset="https://www.grep.sg/wp-content/uploads/2021/11/M240T_info.jpeg 2080w, https://www.grep.sg/wp-content/uploads/2021/11/M240T_info-1280x1280.jpeg 1280w, https://www.grep.sg/wp-content/uploads/2021/11/M240T_info-980x980.jpeg 980w, https://www.grep.sg/wp-content/uploads/2021/11/M240T_info-480x480.jpeg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 2080px, 100vw" /></a></p>
<p class="p1"><span class="s1">The M240T Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.</span></p>
<p class="p1"><span class="s1">The M240T Ethernet Remote I/O module provides 4 RTD inputs, supports PT100 and PT1000 resistance sensor, compatible 2 or 3 wires, the resolution is 0.1°C. All of the I/O with high sampling frequency and special filtering strategy to ensure it’s reliable.</span></p>
<h2 class="p5"><span class="s1">Specifications:</span></h2>
<table class="t1" style="border-style: solid; border-color: #000000;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="td1" colspan="2" valign="middle">
<p class="p1"><span class="s1">Ethernet Remote I/O Module Specifications</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p1"><span class="s1">• RTD Input</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p1"><span class="s1">Sensor Type</span></p>
</td>
<td class="td4" valign="middle">
<p class="p1"><span class="s1">PT100 or PT1000</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">Resolution</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">0.1°C or 0.1 ohm</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p1"><span class="s1">Input Connection</span></p>
</td>
<td class="td4" valign="middle">
<p class="p1"><span class="s1">2- or 3-wire</span></p>
</td>
</tr>
<tr>
<td class="td7" valign="middle">
<p class="p1"><span class="s1">Accuracy</span></p>
</td>
<td class="td8" valign="middle">
<p class="p1"><span class="s1">±0.1% FSR @ 25°C ±0.3% FSR @ -40 and 75°C</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p1"><span class="s1">Sampling frequency</span></p>
</td>
<td class="td4" valign="middle">
<p class="p1"><span class="s1">20Hz</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">Isolation</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">No</span></p>
</td>
</tr>
<tr>
<td class="td1" colspan="2" valign="middle">
<p class="p1"><span class="s1">• Working Power Requirements</span></p>
</td>
</tr>
<tr>
<td class="td7" valign="middle">
<p class="p1"><span class="s1">Input Voltage</span></p>
</td>
<td class="td8" valign="middle">
<p class="p1"><span class="s1">12~36VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p1"><span class="s1">Input Current</span></p>
</td>
<td class="td4" valign="middle">
<p class="p1"><span class="s1">139 mA @ 24 VDC</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p1"><span class="s1">• LAN</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p1"><span class="s1">Ethernet</span></p>
</td>
<td class="td4" valign="middle">
<p class="p1"><span class="s1">10/100 Mbps, RJ45 ports</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">Protection</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">15KV ESD Protection</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p1"><span class="s1">Protocols</span></p>
</td>
<td class="td4" valign="middle">
<p class="p1"><span class="s1">Modbus TCP, TCP/IP</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">Max. TCP Connection</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">5</span></p>
</td>
</tr>
<tr>
<td class="td1" colspan="2" valign="middle">
<p class="p1"><span class="s1">• Serial Port</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">RS485</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">MODBUS- RTU Protocol, Modbus-ASCII Protocol</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p1"><span class="s1">Protection</span></p>
</td>
<td class="td4" valign="middle">
<p class="p1"><span class="s1">15KV ESD Protection</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">Modbus Slave address</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">1~255</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p1"><span class="s1">Baud Rate</span></p>
</td>
<td class="td4" valign="middle">
<p class="p1"><span class="s1">1200,2400,4800,9600,19200,38400,57600,115200,128000Bps;</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">Mapping registers</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">Bit Type: 300 Registers, 16-Bit Type: 300 Registers.300</span></p>
</td>
</tr>
<tr>
<td class="td1" colspan="2" valign="middle">
<p class="p1"><span class="s1">• Physical Characteristics</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">Wiring</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">I/O cable max. 14 AWG</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p1"><span class="s1">Dimensions</span></p>
</td>
<td class="td4" valign="middle">
<p class="p1"><span class="s1">105 x 88 x 30 mm</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">Weight</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">Under 205 g</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p1"><span class="s1">Mounting</span></p>
</td>
<td class="td4" valign="middle">
<p class="p1"><span class="s1">DIN rail or wall</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p1"><span class="s1">• Environmental Limits</span></p>
</td>
</tr>
<tr>
<td class="td9" valign="middle">
<p class="p1"><span class="s1">Operating Temperature</span></p>
</td>
<td class="td10" valign="middle">
<p class="p1"><span class="s1">Standard Models: -10 to 60°C (14 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F)</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">Storage Temperature</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">-40 to 85°C (-40 to 185°F)</span></p>
</td>
</tr>
<tr>
<td class="td9" valign="middle">
<p class="p1"><span class="s1">Ambient Relative Humidity</span></p>
</td>
<td class="td10" valign="middle">
<p class="p1"><span class="s1">5 to 95% (non-condensing)</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p1"><span class="s1">Altitude</span></p>
</td>
<td class="td6" valign="middle">
<p class="p1"><span class="s1">Up to 3000 m</span></p>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h2 class="p5"><span class="s1">Features:</span></h2>
<p class="p1"><span class="s1">1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;</span></p>
<p class="p1"><span class="s1">2. Wide range power supply 12 ~ 36VDC with over voltage and phase-reversal protection;</span></p>
<p class="p1"><span class="s1">3. Management and configuration via LAN connection configuration software for easy operation and maintenance;</span></p>
<p class="p1"><span class="s1">4. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP protocol;</span></p>
<p class="p1"><span class="s1">5. 4 RTD input, supports PT100 and PT1000 resistance sensor, compatible 2 or 3 wires;</span></p>
<p class="p1"><span class="s1">6. High sampling frequency and special filtering strategy to ensure reliability;</span></p>
<p class="p1"><span class="s1">7. 1 RS485 Serial port, supports Modbus RTU/ASCII Master, can extend I/O modules;</span></p>
<p class="p1"><span class="s1">8. Supports register mapping function and extend I/O inquiry strategy;</span></p>
<p class="p1"><span class="s1">9.Provides 1 channel 12~36VDC power source output for external device, saving wiring cost;</span></p>
<p class="p1"><span class="s1">10.LED instructions work status, with reset button to reset, easy on-site installation and commissioning;</span></p>
<p class="p1"><span class="s1">11.Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;</span></p>
<p class="p1"><span class="s1">12.Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.</span></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.grep.sg/product/ethernet-remote-i-o-module-m240t/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">4291</post-id>	</item>
		<item>
		<title>Ethernet Remote I/O Module M230T</title>
		<link>https://www.grep.sg/product/ethernet-remote-i-o-module-m230t/</link>
					<comments>https://www.grep.sg/product/ethernet-remote-i-o-module-m230t/#respond</comments>
		
		<dc:creator><![CDATA[robin]]></dc:creator>
		<pubDate>Wed, 17 Nov 2021 09:04:29 +0000</pubDate>
				<guid isPermaLink="false">https://www.grep.sg/?post_type=product&#038;p=4289</guid>

					<description><![CDATA[<ul>
 	<li class="p1"><span class="s1">Rated Voltage: 12 ~ 36VDC;</span></li>
 	<li class="p1"><span class="s1">4AIN+1RJ45+1 RS485 Serial port, supports Modbus RTU Master or slave, can extend I/O modules;</span></li>
 	<li class="p1"><span class="s1">4 isolated analog input, 12-bit resolution, supports 0~20mA,4~20mA,0-5VDC, 0-10VDC.</span></li>
</ul>]]></description>
										<content:encoded><![CDATA[<p class="p1"><span class="s1">The M230T Ethernet Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1 Industrial 10/100M adaptive Ethernet module inside. It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.</span></p>
<p class="p3"><a href="https://www.grep.sg/wp-content/uploads/2021/11/M230T_info.jpeg"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-4290" src="https://www.grep.sg/wp-content/uploads/2021/11/M230T_info.jpeg" alt="" width="2080" height="2080" srcset="https://www.grep.sg/wp-content/uploads/2021/11/M230T_info.jpeg 2080w, https://www.grep.sg/wp-content/uploads/2021/11/M230T_info-1280x1280.jpeg 1280w, https://www.grep.sg/wp-content/uploads/2021/11/M230T_info-980x980.jpeg 980w, https://www.grep.sg/wp-content/uploads/2021/11/M230T_info-480x480.jpeg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 2080px, 100vw" /></a></p>
<p class="p1"><span class="s1">The M230T Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.</span></p>
<p class="p1"><span class="s1">The M230T Ethernet Remote I/O module provides 4 isolated 12bits analog inputs, supports 0~5V,0~10V,4~20mA,0~20mA analog signal. All of the I/O with high sampling frequency and special filtering strategy to ensure it’s reliable.</span></p>
<h2 class="p5"><span class="s1">Specifications:</span></h2>
<table class="t1" style="height: 1956px; border-style: solid; border-color: #000000;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 51px;">
<td class="td1" style="height: 51px; width: 683.734px;" colspan="2" valign="middle">
<p class="p6"><span class="s1"><b>Ethernet Remote I/O Module Specifications</b></span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td2" style="height: 51px; width: 683.734px;" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Analog Input</b></span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Type</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">Differential input</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Resolution</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">12 bits</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">I/O Mode</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">Voltage / Current (jumper selectable)</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Input Range</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">0 to 10 VDC, 0 to 20 mA, 4 to 20 mA, 4 to 20 mA</span></p>
</td>
</tr>
<tr style="height: 97px;">
<td class="td5" style="height: 97px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Accuracy</span></p>
</td>
<td class="td6" style="height: 97px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">±0.1% FSR @ 25°C</span> <span class="s1">±0.3% FSR @ -10 and 60°C</span> <span class="s1">±0.5% FSR @ -40 and 75°C</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Sampling frequency</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">20Hz</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td7" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Built-in Resistor for Current Input</span></p>
</td>
<td class="td8" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">162 ohms</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Isolation</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">Electrical isolation</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td9" style="height: 51px; width: 683.734px;" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Working Power Requirements</b></span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td10" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Input Voltage</span></p>
</td>
<td class="td11" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">12 to 36 VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Input Current</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">139 mA @ 24 VDC</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td2" style="height: 51px; width: 683.734px;" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Power Output</b></span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Output Voltage</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">12 to 36 VDC</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Output Current</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">139 mA @ 24 VDC</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td9" style="height: 51px; width: 683.734px;" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• LAN</b></span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Ethernet</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">10/100 Mbps, RJ45 ports</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Protection</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">15KV ESD Protection</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Protocols</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">Modbus TCP, TCP/IP</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Max. TCP Connection</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">5</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td2" style="height: 51px; width: 683.734px;" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Serial Port</b></span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">RS485</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p10"><span class="s1">MODBUS- RTU Protocol, Modbus-ASCII Protocol</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Protection</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p10"><span class="s1">15KV ESD Protection</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Modbus Slave address</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p10"><span class="s1">1~255</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Baud Rate</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p10"><span class="s1">1200,2400,4800,9600,19200,38400,57600,115200,128000Bps;</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Mapping registers</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p10"><span class="s1">Bit Type: 300 Registers, 16-Bit Type: 300 Registers.</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td2" style="height: 51px; width: 683.734px;" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Physical Characteristics</b></span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Wiring</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">I/O cable max. 14 AWG</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Dimensions</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">105 x 88 x 30 mm</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Weight</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">Under 205 g</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Mounting</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">DIN rail or wall</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td9" style="height: 51px; width: 683.734px;" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Environmental Limits</b></span></p>
</td>
</tr>
<tr style="height: 74px;">
<td class="td7" style="height: 74px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Operating Temperature</span></p>
</td>
<td class="td8" style="height: 74px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">Standard Models: -10 to 60°C (14 to 140°F)</span> <span class="s1">Wide Temp. Models: -40 to 75°C (-40 to 167°F)</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Storage Temperature</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">-40 to 85°C (-40 to 185°F)</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Ambient Relative Humidity</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">5 to 95% (non-condensing)</span></p>
</td>
</tr>
<tr style="height: 51px;">
<td class="td3" style="height: 51px; width: 216.891px;" valign="middle">
<p class="p8"><span class="s1">Altitude</span></p>
</td>
<td class="td4" style="height: 51px; width: 464.844px;" valign="middle">
<p class="p9"><span class="s1">Up to 3000 m</span></p>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h2 class="p5"><span class="s1">Features:</span></h2>
<p class="p1"><span class="s1">1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;</span></p>
<p class="p1"><span class="s1">2. Wide range power supply 12 ~ 36VDC with over voltage and phase-reversal protection;</span></p>
<p class="p1"><span class="s1">3. Management and configuration via LAN connection configuration software for easy operation and maintenance;</span></p>
<p class="p1"><span class="s1">4. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP protocol;</span></p>
<p class="p1"><span class="s1">5. 4 isolated analog input, 12-bit resolution, supports 0~20mA,4~20mA,0-5VDC, 0-10VDC;</span></p>
<p class="p1"><span class="s1">6. High sampling frequency and special filtering strategy to ensure reliability;</span></p>
<p class="p1"><span class="s1">7. 1 RS485 Serial port, supports Modbus RTU Master and slave, can extend I/O modules;</span></p>
<p class="p1"><span class="s1">8. Supports register mapping function and extend I/O inquiry strategy;</span></p>
<p class="p1"><span class="s1">9.Provides 1 channel 12~36VDC power source output for external device, saving wiring cost;</span></p>
<p class="p1"><span class="s1">10.LED instructions work status, with reset button to reset, easy on-site installation and commissioning;</span></p>
<p class="p1"><span class="s1">11.Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;</span></p>
<p class="p1"><span class="s1">12.Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.</span></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.grep.sg/product/ethernet-remote-i-o-module-m230t/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">4289</post-id>	</item>
		<item>
		<title>Ethernet Remote I/O Module M220T</title>
		<link>https://www.grep.sg/product/ethernet-remote-i-o-module-m220t/</link>
					<comments>https://www.grep.sg/product/ethernet-remote-i-o-module-m220t/#respond</comments>
		
		<dc:creator><![CDATA[robin]]></dc:creator>
		<pubDate>Wed, 17 Nov 2021 08:59:38 +0000</pubDate>
				<guid isPermaLink="false">https://www.grep.sg/?post_type=product&#038;p=4287</guid>

					<description><![CDATA[<ul>
 	<li class="p1"><span class="s1">Rated Voltage: 12 ~ 36VDC;</span></li>
 	<li class="p1"><span class="s1">4DO+1RJ45+1 RS485 Serial port, supports Modbus RTU Master or slave, can extend I/O modules;</span></li>
 	<li class="p1"><span class="s1">DO Sink or Pulse Output.</span></li>
</ul>]]></description>
										<content:encoded><![CDATA[<p class="p1"><span class="s1">The M220T Ethernet Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1 Industrial 10/100M adaptive Ethernet module inside. It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.</span></p>
<p class="p1"><span class="s1">The M220T Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.</span></p>
<p class="p3"><a href="https://www.grep.sg/wp-content/uploads/2021/11/M220T_info.jpeg"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-4288" src="https://www.grep.sg/wp-content/uploads/2021/11/M220T_info.jpeg" alt="" width="2080" height="2080" srcset="https://www.grep.sg/wp-content/uploads/2021/11/M220T_info.jpeg 2080w, https://www.grep.sg/wp-content/uploads/2021/11/M220T_info-1280x1280.jpeg 1280w, https://www.grep.sg/wp-content/uploads/2021/11/M220T_info-980x980.jpeg 980w, https://www.grep.sg/wp-content/uploads/2021/11/M220T_info-480x480.jpeg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 2080px, 100vw" /></a></p>
<p class="p1"><span class="s1">The M220T Ethernet Remote I/O module provides 4 digital outputs, supports 10Hz~300Khz high speed pulse output or relay outputs. All of the I/O with high sampling frequency and special filtering strategy to ensure it’s reliable.</span></p>
<h2 class="p5"><span class="s1">Specifications:</span></h2>
<table class="t1" style="border-style: solid; border-color: #000000;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="td1" colspan="2" valign="middle">
<p class="p6"><span class="s1"><b>Ethernet Remote I/O Module Specifications</b></span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Digital Output</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Type</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Sink</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">I/O Mode</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">DO or Pulse Output</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p8"><span class="s1">Pulse Output Frequency</span></p>
</td>
<td class="td6" valign="middle">
<p class="p9"><span class="s1">10Hz~300KHz(Only the 1</span><span class="s2"><sup>st</sup></span><span class="s1"> Channel can be used as high speed pulse outputs)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Over-Voltage Protection</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">50 VDC</span></p>
</td>
</tr>
<tr>
<td class="td7" valign="middle">
<p class="p8"><span class="s1">Over-Temperature Shutdown</span></p>
</td>
<td class="td8" valign="middle">
<p class="p9"><span class="s1">175°C (typical), 150°C (min.)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Load Current</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Max. 500 mA per channel</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Digital sampling frequency</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">500Hz</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p8"><span class="s1">Isolation</span></p>
</td>
<td class="td6" valign="middle">
<p class="p9"><span class="s1">If DO is Sink type, then no isolation. If it is Relay, then is electrical isolation.</span></p>
</td>
</tr>
<tr>
<td class="td9" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Working Power Requirements</b></span></p>
</td>
</tr>
<tr>
<td class="td7" valign="middle">
<p class="p8"><span class="s1">Input Voltage</span></p>
</td>
<td class="td8" valign="middle">
<p class="p9"><span class="s1">12 to 36 VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Input Current</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">139 mA @ 24 VDC</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• LAN</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Ethernet</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">10/100 Mbps, RJ45 ports</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Protection</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">15KV ESD Protection</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Protocols</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Modbus TCP, TCP/IP,MQTT,TCP Server, TCP Client</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Max. TCP Connection</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">5</span></p>
</td>
</tr>
<tr>
<td class="td9" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Serial Port</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">RS485</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">MODBUS- RTU Protocol, Modbus-ASCII Protocol</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Protection</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">15KV ESD Protection</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Modbus Slave address</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">1~255</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Baud Rate</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">1200,2400,4800,9600,19200,38400,57600,115200,128000Bps;</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Mapping registers</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">Bit Type: 300 Registers, 16-Bit Type: 300 Registers.300</span></p>
</td>
</tr>
<tr>
<td class="td9" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Physical Characteristics</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Wiring</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">I/O cable max. 14 AWG</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Dimensions</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">105 x 88 x 30 mm</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Weight</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Under 205 g</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Mounting</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">DIN rail or wall</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Environmental Limits</b></span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p8"><span class="s1">Operating Temperature</span></p>
</td>
<td class="td6" valign="middle">
<p class="p9"><span class="s1">Standard Models: -10 to 60°C (14 to 140°F)</span> <span class="s1">Wide Temp. Models: -40 to 75°C (-40 to 167°F)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Storage Temperature</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">-40 to 85°C (-40 to 185°F)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Ambient Relative Humidity</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">5 to 95% (non-condensing)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Altitude</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Up to 3000 m</span></p>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h2 class="p5"><span class="s1">Features:</span></h2>
<p class="p1"><span class="s1">1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;</span></p>
<p class="p1"><span class="s1">2. Wide range power supply 12 ~ 36VDC with over voltage and phase-reversal protection;</span></p>
<p class="p1"><span class="s1">3. Management and configuration via LAN connection configuration software for easy operation and maintenance;</span></p>
<p class="p1"><span class="s1">4. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP protocol;</span></p>
<p class="p1"><span class="s1">5. 4 digital output or relay output, supports 10Hz~300KHz high speed pulse output;</span></p>
<p class="p1"><span class="s1">6. High sampling frequency and special filtering strategy to ensure reliability;</span></p>
<p class="p1"><span class="s1">7. 1 RS485 Serial port, supports Modbus RTU/ASCII Master, can extend I/O modules;</span></p>
<p class="p1"><span class="s1">8. Supports register mapping function and extend I/O inquiry strategy;</span></p>
<p class="p1"><span class="s1">9.Provides 1 channel 12~36VDC power source output for external device, saving wiring cost;</span></p>
<p class="p1"><span class="s1">10.LED instructions work status, with reset button to reset, easy on-site installation and commissioning;</span></p>
<p class="p1"><span class="s1">11.Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;</span></p>
<p class="p1"><span class="s1">12.Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.</span></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.grep.sg/product/ethernet-remote-i-o-module-m220t/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">4287</post-id>	</item>
		<item>
		<title>Ethernet Remote I/O Module M210T</title>
		<link>https://www.grep.sg/product/ethernet-remote-i-o-module-m210t/</link>
					<comments>https://www.grep.sg/product/ethernet-remote-i-o-module-m210t/#respond</comments>
		
		<dc:creator><![CDATA[robin]]></dc:creator>
		<pubDate>Wed, 17 Nov 2021 08:53:24 +0000</pubDate>
				<guid isPermaLink="false">https://www.grep.sg/?post_type=product&#038;p=4285</guid>

					<description><![CDATA[<ul>
 	<li class="p1"><span class="s1">Rated Voltage: 12 ~ 36VDC;</span></li>
 	<li class="p1"><span class="s1">4DIN+1RJ45+1 RS485 Serial port, supports Modbus RTU Master or slave, can extend I/O modules;</span></li>
 	<li class="p1"><span class="s1">Wet Contact (NPN or PNP), Dry Contact;</span></li>
</ul>]]></description>
										<content:encoded><![CDATA[<p class="p1"><span class="s1">The M210T Ethernet Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1 Industrial 10/100M adaptive Ethernet module inside. It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.</span></p>
<p class="p3"><a href="https://www.grep.sg/wp-content/uploads/2021/11/M210T_info.jpeg"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-4286" src="https://www.grep.sg/wp-content/uploads/2021/11/M210T_info.jpeg" alt="" width="2080" height="2080" srcset="https://www.grep.sg/wp-content/uploads/2021/11/M210T_info.jpeg 2080w, https://www.grep.sg/wp-content/uploads/2021/11/M210T_info-1280x1280.jpeg 1280w, https://www.grep.sg/wp-content/uploads/2021/11/M210T_info-980x980.jpeg 980w, https://www.grep.sg/wp-content/uploads/2021/11/M210T_info-480x480.jpeg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 2080px, 100vw" /></a></p>
<p class="p1"><span class="s1">The M210T Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.</span></p>
<p class="p1"><span class="s1">The M210T Ethernet Remote I/O module provides 4 optical-isolated digital inputs, supports max. 700KHz high speed pulse counter. All of the I/O with high sampling frequency and special filtering strategy to ensure it’s reliable.</span></p>
<h2 class="p5"><span class="s1">Specifications:</span></h2>
<table class="t1" style="border-style: solid; border-color: #000000;" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="td1" colspan="2" valign="middle">
<p class="p6"><span class="s1"><b>Ethernet Remote I/O Module Specifications</b></span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Digital Input</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Sensor Type</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Wet Contact (NPN or PNP), Dry Contact</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">I/O Mode</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">DI or Event Counter</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p8"><span class="s1">Dry Contact</span></p>
</td>
<td class="td6" valign="middle">
<p class="p9"><span class="s1">• On: short to GND=1</span> <span class="s1">• Off: open=0</span></p>
</td>
</tr>
<tr>
<td class="td7" valign="middle">
<p class="p8"><span class="s1">Wet Contact (DI to COM)</span></p>
</td>
<td class="td8" valign="middle">
<p class="p9"><span class="s1">• On: 10 to 30 VDC=1 </span> <span class="s1">• Off: 0 to 3 VDC=0</span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p8"><span class="s1">Counter Frequency</span></p>
</td>
<td class="td6" valign="middle">
<p class="p9"><span class="s1">Max. 700Khz (Only the 1</span><span class="s3"><sup>st</sup></span><span class="s1"> Channel can be used as high speed pulse counter)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Digital sampling frequency</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">500Hz</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Digital filtering strategy</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Continues 3 times</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Isolation</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Optical Isolated,3k VDC or 2k Vrms</span></p>
</td>
</tr>
<tr>
<td class="td9" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Working Power Requirements</b></span></p>
</td>
</tr>
<tr>
<td class="td7" valign="middle">
<p class="p8"><span class="s1">Input Voltage</span></p>
</td>
<td class="td8" valign="middle">
<p class="p9"><span class="s1">12 to 36 VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Input Current</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">139 mA @ 24 VDC</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Power Output</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Output Voltage</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">12 to 36 VDC</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Output Current</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">139 mA @ 24 VDC</span></p>
</td>
</tr>
<tr>
<td class="td9" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• LAN</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Ethernet</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">10/100 Mbps, RJ45 ports</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Protection</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">15KV ESD Protection</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Protocols</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Modbus TCP, TCP/IP</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Max. TCP Connection</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">5</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Serial Port</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">RS485</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">MODBUS- RTU Protocol, Modbus-ASCII Protocol</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Protection</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">15KV ESD Protection</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Modbus Slave address</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">1~255</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Baud Rate</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">1200,2400,4800,9600,19200,38400,57600,115200,128000Bps;</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Mapping registers</span></p>
</td>
<td class="td4" valign="middle">
<p class="p10"><span class="s1">Bit Type: 300 Registers, 16-Bit Type: 300 Registers.</span></p>
</td>
</tr>
<tr>
<td class="td2" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Physical Characteristics</b></span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Wiring</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">I/O cable max. 14 AWG</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Dimensions</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">105 x 88 x 30 mm</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Weight</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Under 205 g</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Mounting</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">DIN rail or wall</span></p>
</td>
</tr>
<tr>
<td class="td9" colspan="2" valign="middle">
<p class="p7"><span class="s1"><b>• Environmental Limits</b></span></p>
</td>
</tr>
<tr>
<td class="td5" valign="middle">
<p class="p8"><span class="s1">Operating Temperature</span></p>
</td>
<td class="td6" valign="middle">
<p class="p9"><span class="s1">Standard Models: -10 to 60°C (14 to 140°F)</span> <span class="s1">Wide Temp. Models: -40 to 75°C (-40 to 167°F)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Storage Temperature</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">-40 to 85°C (-40 to 185°F)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Ambient Relative Humidity</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">5 to 95% (non-condensing)</span></p>
</td>
</tr>
<tr>
<td class="td3" valign="middle">
<p class="p8"><span class="s1">Altitude</span></p>
</td>
<td class="td4" valign="middle">
<p class="p9"><span class="s1">Up to 3000 m</span></p>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h2 class="p5"><span class="s1">Features:</span></h2>
<p class="p1"><span class="s1">1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;</span></p>
<p class="p1"><span class="s1">2. Wide range power supply 12 ~ 36VDC with over voltage and phase-reversal protection;</span></p>
<p class="p1"><span class="s1">3. Management and configuration via LAN connection configuration software for easy operation and maintenance;</span></p>
<p class="p1"><span class="s1">4. Support Web realtime monitoring and Web debugging;  </span></p>
<p class="p1"><span class="s1">5. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP protocol;</span></p>
<p class="p1"><span class="s1">6. 4 optical isolated digital input, supports max. 700khz high speed pulse counter;</span></p>
<p class="p1"><span class="s1">7. High sampling frequency and special filtering strategy to ensure reliability;</span></p>
<p class="p1"><span class="s1">8. 1 RS485 Serial port, supports Modbus RTU/ASCII Master, can extend I/O modules;</span></p>
<p class="p1"><span class="s1">9. Supports register mapping function and extend I/O inquiry strategy;</span></p>
<p class="p1"><span class="s1">10.Provides 1 channel 12~36VDC power source output for external device, saving wiring cost;</span></p>
<p class="p1"><span class="s1">11.LED instructions work status, with reset button to reset, easy on-site installation and commissioning;</span></p>
<p class="p1"><span class="s1">12.Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;</span></p>
<p class="p1"><span class="s1">13.Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.</span></p>
]]></content:encoded>
					