Ethernet Remote I/O Module M200T

Ethernet Remote I/O Module M200T

SGD 231

  • Rated Voltage: 12 ~ 36VDC;
  • 2AO+1RJ45, 12-bit resolution, supports 0-10VDC;
  • 1 RS485 Serial port, supports Modbus RTU Master or slave, can extend I/O modules
Category:

The M200T Ethernet Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1 Industrial 10/100M adaptive Ethernet module inside.It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems.It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.

The M200T provides a RS485 interface, through the RS485 bus,it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function,the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.

The M200T Ethernet Remote I/O module provides 2 analog outputs, 12-bit resolution, supports 0~10VDC signal output. All of the I/O with high sampling frequency and special filtering strategy to ensure it's reliable.

Specifications:

Ethernet Remote I/O Module Specifications

• Analog Output

Type

Differential input

Resolution

12 bits

Output Range

0 to 10 VDC

Drive Current

1A (max.)

Accuracy

±0.1% FSR @ 25°C ±0.3% FSR @ -10 and 60°C ±0.5% FSR @ -40 and 75°C

Load Resistor

Internal register, 400 ohms

Isolation

No

• Working Power Requirements

Input Voltage

24 to 36 VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;

Input Current

139 mA @ 24 VDC

• Power Output

Output Voltage

24 to 36 VDC

Output Current

139 mA @ 24 VDC

• LAN

Ethernet

10/100 Mbps, RJ45 ports

Protection

15KV ESD Protection

Protocols

Modbus TCP, TCP/IP

Max. TCP Connection

5

• Serial Port

RS485

MODBUS- RTU Protocol, Modbus-ASCII Protocol, Modbus Master only.

Protection

15KV ESD Protection

Modbus Slave address

1~255

Baud Rate

1200,2400,4800,9600,19200,38400,57600,115200,128000Bps;

Mapping registers

Bit Type: 300 Registers, 16-Bit Type: 300 Registers.

• Physical Characteristics

Wiring

I/O cable max. 14 AWG

Dimensions

105 x 88 x 30 mm

Weight

Under 205 g

Mounting

DIN rail or wall

• Environmental Limits

Operating Temperature

Standard Models: -10 to 60°C (14 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F)

Storage Temperature

-40 to 85°C (-40 to 185°F)

Ambient Relative Humidity

5 to 95% (non-condensing)

Altitude

Up to 3000 m

Features:

1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;

2. Wide range power supply 24 ~ 36VDC with over voltage and phase-reversal protection;

3. Management and configuration via LAN connection configuration software for easy operation and maintenance;

4. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP protocol;

5. 2 analog output, 12-bit resolution, supports 0-10VDC;

6. High sampling frequency and special filtering strategy to ensure reliability;

7. 1 RS485 Serial port, supports Modbus RTU/ASCII Master, can extend I/O modules;

8. Supports register mapping function and extend I/O inquiry strategy;

9. Provides 1 channel 24~36VDC power source output for external device, saving wiring cost;

10. LED instructions work status, with reset button to reset, easy on-site installation and commissioning;

11. Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field.

Reviews

There are no reviews yet.

Be the first to review “Ethernet Remote I/O Module M200T”

Your email address will not be published. Required fields are marked *